Concrete chiller

Concrete mixing plant chiller

Water cooled/ evaporation cooled chiller

Chiller for concrete mixing plant cooling


Views:763 次

Introduction

Icesnow concrete cooling water chiller.  Icesnow produced water chiller, containerized chiller, low temperature water chiller, small capacity low temperature chiller with different models and competitive price. The outlet water temperature can be set at 0.5 ℃ to 20 ℃. Icesnow water chiller gained its patent, the patent number is ZL2011120240739.1. Icesnow water chiller can be used for large construction project cooling, concrete mixing cooling project, concrete cooling etc. Icesnow is the manufacturer of industrial water chiller and container water chiller.  Welcome to contact us! Email: sales@icesnow.cn

The necessity of concrete cooling:

During the process of concrete mixing, concrete hydration is an exothermic chemical reaction process, which will cause a lot of heat.

Concrete mixing plant chiller:

Icesnow concrete mixing plant chiller is containerized design, which is easy for moving to other construction sites. It can lower the water temperature from 36ºC to 0.5ºC. (It can be applicable for higher inlet temperature) Icesnow chiller uses evaporation condenser or shell and tube condenser, secondary water cooling system. Icesnow water chillers are in higher efficiency, equipping with PLC device can control the outlet temperature. The energy can be saved by 25% comparing with ordinary chiller and the temperature can be chilled from 45-50°C to 0.5-1℃. Used high efficient plate heat exchanger, the chiller we offered is more energy saving, occupy less space and more reliable.

Concrete cooling chiller advantages:

1. The outlet water temperature can be set at 0.5 ℃ to 20 ℃, Accurate to ± 0.1 ℃
2. Intelligent automatic control. The system can automatically adjust the compressor and keep the water temperature stable.
3. The refrigeration unit uses efficient plate heat exchanger, which has higher cooling efficiency and is energy saving.
4. High flow volume: the flow of water varies from 1.5m³/h to 24 m³/h, which can meet different needs.
5. Container design, easy for transportation and convenient for maintenance. 
6. Has national patent, the patent number: ZL2011120240739.1

Chiller working theory:

The liquid refrigerant of the evaporator absorbs heat from the water and begins to evaporate, forming a temperature gap between the refrigerant and the water, the liquid refrigerant is evaporated into gas and is completely sucked into the compressor and compressed, the gas refrigerant absorbs heat through the condenser, condensing into liquid. Through the expansion valve, the liquid refrigerant becomes low temperature low pressure refrigerant into the evaporator, reducing the water temperature to complete the whole process.

Chiller special design:

1. The whole refrigeration system is safer and stable
2. The outlet water temperature can be set at 0.5 ℃ to 20 ℃, accurate to ± 0.1 ℃. It can be set according to your special need.
3. Constant water temperature. The system can automatically adjust the compressor and keep the water temperature stable.
4. Water outlet way: straight outlet type. Different from the ordinary recycle water outlet way, Icesnow low temperature water chiller can offer the low temperature water directly for use.
5. High flow volume: the flow of water varies from 1.5m³/h to 24 m³/h, which can meet the need of big concrete mixing projects.

 

Chiller technique parameter:

Chiller technique parameter
Model

Daily output(m³)

Water tank volume(m³)

Neccessary Refrigeration capacity(kw)

Installed refrigeration capacity(kw)

Coefficient of surplusTotal power(kw)

Cop(kw)

Container size(ft)

ISCW36361264.982.21.320.24.120"
ISCW606020108.1112.1126.64.220"
ISCW727224129.8147.11.133.44.420"
ISCW969632173195.21.144.54.4

20"

ISCW12012040216.3252.51.254.64.6

20"

ISCW15615652281.2291.9163.24.620"
ISCW18018060324.4347.91.176.74.520"
ISCW24024080432.6437.1194.14.640"
ISCW312312104562.3626.71.1130.44.840"
ISCW360360120648.8688.31.1144.74.840"
ISCW480480160865.1874.21188.24.640"
ISCW5765761921038.11076.21226.44.840"

The design condition: the highest temperature is 50°C, power supply: 3P/380V/50HZ, highest inlet temperature: 45°C, refrigerant: R22 or R404A, outlet temperature: 0.5~ 20°C, wet-bulb temperature: 30°C, working time: 24h/day.

Application industries:
Icesnow water chillers are widely used  for large concrete engineering construction enterprises, concrete plant cooling projects, construction projects, hydraulic and hydroelectric engineering, nuclear power engineering, mine cooling, preservation cooling,instant cooling, concrete mixing project, chemical industry , pharmaceutical industry, slaughter processing cooling, printing and dyeing processing etc.
 